Home of the original IBM PC emulator for browsers.
[PCjs Machine "ibm5170"]
Waiting for machine "ibm5170" to load....
Disk No: 2615
Disk Title: Kwikstat 3 of 3 (#654, #655 also)
PC-SIG Version: S2.11
Program Title: Kwikstat
Author Version: 2.10
Author Registration: $49.00
Special Requirements: 384K RAM and CGA. Hard drive recommended.
KWIKSTAT is a scientific statistical analysis system complete with
graphics. You can import ASCII files, dBase III files or build your own
databases. KWIKSTAT is menu-driven, with six separate modules:
~ DATA -- Create a database, enter and edit data.
~ REPORTS -- Export data to another program; display the structure of a
selected database and access DOS without exiting.
~ STAT1 -- Descriptive statistics and graphical representations such
as histograms, scatterplots and box plots.
~ STAT2 -- Explore comparative statistics with t-tests on paired or
matched data and one way analysis of variance (ANOVA).
~ STAT3 -- Perform simple linear and multiple regression analyses.
~ STAT4 -- Deal with various methods to analyze categorical data, as
opposed to measured data.
PC-SIG
1030D East Duane Avenue
Sunnyvale Ca. 94086
(408) 730-9291
(c) Copyright 1989 PC-SIG, Inc.
╔═════════════════════════════════════════════════════════════════════════╗
║ <<<< PC-SIG Disk #2615 KWIKSTAT >>>> ║
║ Disk 3 of 3 (also #654 and #655) ║
╠═════════════════════════════════════════════════════════════════════════╣
║ ║
║ To begin the Simulations Module, type: README (press Enter) ║
║ ║
║ To install KWIKSTAT, insert Disk 1 and type: README (press Enter) ║
║ ║
║ To print a copy of the order form from Disk 1, type: ║
║ COPY ORDER PRN (press Enter) ║
║ ║
║ ║
║ Copyright 1991, PC-SIG, Inc. ║
╚═════════════════════════════════════════════════════════════════════════╝
Kwikstat 2.10
Kwikstat Simulations Module
(c)TexaSoft, 1990
ALL RIGHTS RESERVED
All rights reserved. Printed in the United States of America. No
part of this book may be reproduced without prior permission. For
information, address TexaSoft, P.O. Box 1169, Cedar Hill, Texas
75104.
No patent liability is assumed with respect to the use of the
information contained herein. While every precaution has been taken
in the preparation of this publication, the publisher assumes no
responsibility for errors or omissions. Neither is any liability
assumed for damages resulting from the use of the information
herein.
INSTALLING KWIKSTAT SUPPLEMENT ON YOUR HARD DISK
A hard disk is recommended for using KWIKSTAT, although individual
programs can be run from a floppy disk. The procedure described
here loads this KWIKSTAT supplemental program on the hard disk
drive C:, in a subdirectory named C:\KWIKSTAT.
Place the KWIKSTAT SIMULATIONS DISK in drive A:. Make disk A: the
default drive, by entering the command:
C>A:
(or you can use B: if your disk drive does not fit disk A:) Next,
enter the command:
A>KSLOAD C:\KWIKSTAT\
(There is a space after the command KSLOAD). If your Kwikstat
programs are on another disk drive or directory, change the command
to reflect its location. You need to have version 2.10 or higher of
Kwikstat, with EXE files dated 10-1-90 or later for the menu to
work properly. Install the Kwikstat basic modules BEFORE installing
any supplemental program.
________________________________________________________
Please Register
1
Kwikstat Simultations Module
________________________________________________________
FLOPPY DRIVE INSTALLATION
Place the KWIKSTAT SIMULATIONS disk in drive A: and the disk where
you want it to reside in drive B:, and enter the command:
A>KSLOAD B:\
The B: disk must have the files BRT70EFR.EXE, KSMENU.INI and
KWIKSTAT.HLP on the disk. Also, make sure the disk has enough
space for the copy to take place (about 80K).
INSTRUCTIONS FOR OPERATION
From the hard disk prompt "C", get into the KWIKSTAT directory
using the command:
C>CD \KWIKSTAT
To begin KWIKSTAT, enter the command:
C>KS
The SUPPLEMENTAL program will appear on the Kwikstat menu. If it
does not, please check to see that you have performed the
installation properly.
LATENEWS
If it exists, print the file LATENEWS.DOC to get the latest
information on Kwikstat. It may include information on new features
or changes not included in this manual. Please check the main
Kwikstat manual for information on monitor and path setup
procedures and error codes.
DATA GENERATION AND SIMULATION
The Kwikstat Data Generation and simulation module is used to
generate sample datasets for Kwikstat and to display simulation of
some common statistical concepts. The screen for this module is
illustrated below:<$&menu[v]>
A)GENERATE DATA SETS
This option allows you to create Kwikstat (dBASE) data sets from a
Normal, Uniform or Exponential distribution. You will be asked to
specify the number of variables (columns in the database) to
generate. Then for each variable, you must specify if it is to be
from a Normal, Uniform or Exponential distribution.
________________________________________________________
Please Register
2
Kwikstat Simultations Module
________________________________________________________
If the data is to be from a Normal Distribution, you must specify
the mean and standard deviation of the variable. If the data is
from a uniform distribution, you will be asked to specify the
minimum and maximum of the distribution. You can examine the
generated data sets in the Kwikstat Descriptive statistics module.
See also option E to display a list of the dataset..
B)95% CONFIDENCE INTERVAL SIMULATION
The 95% Confidence Interval simulation shows visually the meaning
of a 95% confidence interval. That is, if you take 100 samples from
a population and calculate a 95% C.I. for each sample, you would
expect about 95 of the 100 C.I. ranges to include the actual mean
of the population.
In this simulation, 100 samples of size 30 are drawn from a
normally distributed distribution and a 95% C.I. is calculated for
each sample. The true mean of the population is plotted
horizontally on the screen. Each C.I. is plotted vertically on the
screen so you can visually see if the range of the C.I. covers the
true population mean. All 100 C.I.'s are plotted and a summary of
how many covered the mean is displayed on the screen. To see what
is meant by "about 95" will cover the mean, repeat this simulation
several times. You will see that the number covering the mean will
range from the 80s to 100, but will average about 95 over a period
of trials.
C)DEMONSTRATE CENTRAL LIMIT THEOREM
The Central Limit Theorem states that if samples of size n are
taken from a population with an arbitrary distribution, the
distribution of the means of the samples approaches normality as
the size of the (n) sample increases. NOTE:If you are using a PC
with an 8088 chip and no math co-processor, the generation of the
Normal population will take as much as 2 to 3 minutes.
In this demonstration, a population of 500 points is generated from
either a Normal, Uniform or Exponential distribution. Then, 100
samples of sizes 2, 3, 5, 10 and 30 are taken from the population.
A histogram of the original population is displayed on the left
side of the computer screen and a histogram of the sample is
displayed on the right side of the screen. As each sample is
displayed, you can see how the larger sample size makes the right
side histogram approach a bell-shape. Also, as the sample size
increases, the spread of the histogram gets smaller (the standard
deviation).
The demonstration will automatically cycle through the 5 sizes of
samples. To cancel the demonstration, press the Esc key. This will
________________________________________________________
Please Register
3
Kwikstat Simultations Module
________________________________________________________
cause the demonstration to stop once the current sample has been
displayed.
D)FLIP A COIN DEMONSTRATION
When you flip a fair coin, you would expect to get about the same
number of heads and tails over a long period of time. This
simulation automates 100 coin tosses and graphs the results. You
should repeat this simulation a number of times to see how the
graph varies for different series of flips.
E)LIST VALUES FROM A DATABASE TO THE SCREEN
This option allows you to display the contents of a database to the
screen. This is the sample as the "Kwiklook" option in the DATA
module. Its purpose here is to allow you to example databases that
you have created in this module without having to go to another
module.
________________________________________________________
Please Register
4
Kwikstat Simultations Module
________________________________________________________
ORDER BLANK SN:KS21090s
KWIKSTAT BASIC PACKAGE (7 modules), printed manual, latest
version, registration, 2 disks ($49) x _______= $____________
Extra KWIKSTAT Manuals ($10 each) x _______= $____________
KWIKSTAT 2-WAY ANOVA Supplemental program $19 x_____= $____________
KWIKSTAT TIME SERIES Supplemental program $19 x_____= $____________
Note:You need the KWIKSTAT BASIC package to run supplemental programs.
KWIKSTAT PLUS package, includes BASIC PACKAGE plus both
SUPPLEMENTS, 4 disks (9 total modules) $79 x_____= $____________
Normal registration includes 90 day phone support. You may extend
support to 1 year, plus automatically receive all updates during the
year. EXTENDED SUPPORT & UPDATES/YEAR $40 x_____= $____________
SUB TOTAL $____________
Texas Residents add 7.25% sales tax $____________
Add $4 P&H, $8 if PO, COD or RUSH or $10 if overseas $____________
TOTAL ENCLOSED $
============
-------------------------------------------------------------------
Specify: ____5 1/4 inch disk or ____ 3.5 inch disk
-------------------------------------------------------------------
Check one:___Check or M.O. ___MC ___VISA ___ P.O. #___________
-------------------------------------------------------------------
IF CREDIT CARD:Name on card:_________________________________
Card Number is:____________________________Exp Date__________
Authorized Signature:________________________________________
-------------------------------------------------------------------
Mail order to:_______________________________________________
Address:_____________________________________________________
City, State, Zip:____________________________________________
Phone ( )_________________________________________________
-------------------------------------------------------------------
Where did you hear about Kwikstat?_________________________________
-------------------------------------------------------------------
Mail to:TexaSoft, P.O. Box 1169, Cedar Hill, TX 75104. Thanks!
Guaranteed satisfaction or return for a full refund. Phone
Orders (Visa, MasterCard): Call 214-291-2115. FAX:214-291-3400.
5
Volume in drive A has no label
Directory of A:\
KSSMEN 44 10-15-90 2:11a
README BAT 1004 10-15-90 2:11a
KSDEMO COM 10034 10-15-90 2:11a
PRINTDOC COM 7282 10-15-90 2:11a
KSSIMU DOC 11217 10-15-90 2:11a
BRT70EFR EXE 83728 10-15-90 2:11a
KSSIMU EXE 43456 10-15-90 2:11a
KSMENU INI 518 10-15-90 2:11a
KSTAT INI 121 10-15-90 2:11a
KSLOAD BAT 2175 10-15-90 2:11a
DEMO BAT 322 10-15-90 2:11a
FILE2615 TXT 2517 4-25-91 2:53p
GO BAT 38 1-31-91 12:58a
GO TXT 1156 1-01-80 7:04a
14 file(s) 163612 bytes
150528 bytes free