Home of the original IBM PC emulator for browsers.
[PCjs Machine "ibm5170"]
Waiting for machine "ibm5170" to load....
Disk No: 1981
Disk Title: The Electrical DBS Disk Disk 5 of 5
PC-SIG Version: S1
Program Title: The Electrical DBS disk
Author Version: 02/12
Author Registration: $45.00
Special Requirements: None.
THE ELECTRICAL REFERENCE DATABASE gives electricians, engineers,
designers, and panel shop operators one place on your computer where you
can go to and find those little notes that only experience produces. In
this case an experienced professional has given you his experience and
created a forum for you to add your own.
Databases include:
~ D.C. MOTORS
~ SINGLE PHASE MOTORS
~ THREE PHASE INDUCTION MOTORS
~ THREE PHASE WOUND ROTOR MOTORS
~ THREE PHASE SYNCHRONOUS MOTORS
~ NEMA DATA
~ MOTOR FRAME SIZES
~ THREE PHASE CONDUCTORS AMPACITIES
~ SINGLE PHASE CONDUCTOR AMPACITIES
~ MAXIMUM CONDUCTORS IN CONDUIT
~ THREE PHASE TRANSFORMERS
~ RECOMMENDED COPPER WIRE AND TRANSFORMER SIZES
Motor databases provide information as to full load currents, motor over
current protection rating, the size or guage of the wire required to
connect one motor of that particular horsepower in a general purpose
application, the conduit trade size required to house the wire, the NEMA
size starter recommended,the amperage and the recommended fusing.
The present data is referred to as "seed" data just to get you started.
You may add and delete data as you like. Each data base may can handle
a maximum of 32000 entries.
Each database is menu-driven and complete with it's own help function
and notes field. Use this data base as a tool - not as a replacement
for the NATIONAL ELECTRICAL CODE manual! All information assumes a
single motor installation. Consult your N.E.C. manual for the details
of your particular installation.
PC-SIG
1030D East Duane Avenue
Sunnyvale Ca. 94086
(408) 730-9291
(c) Copyright 1989 PC-SIG, Inc.
Volume in drive A has no label
Directory of A:\
NEC COM 19049 1-01-80 1:51a
YOURSYS COM 26516 9-22-87 1:25a
SBMIO COM 11291 9-22-87 1:25a
MESSAGE 1 178 1-01-80 12:51a
RUN BAT 64 1-01-80 12:47a
SBMSIO CHN 27209 9-22-87 1:25a
MANUAL DOC 5802 1-01-80 12:32a
HELP TXT 2762 9-22-87 1:25a
THREXFMR CHN 23128 1-01-80 12:35a
FILES_5 DOC 0 2-12-89 11:23a
10 File(s) 240640 bytes free
╔═════════════════════════════════════════════════════════════════════════╗
║ <<<< Disk #1981 THE ELECTRICAL DBS DISK >>>> ║
║ (disk 5 of 5, 1977, 1978, 1979, 1980 also) ║
╠═════════════════════════════════════════════════════════════════════════╣
║ To install files onto your hard drive, insert disk 1 and type: INSTALL ║
║ ║
║ To start program, type: RUN (press enter) ║
║ ║
║ To print documentation, type: COPY MANUAL.DOC PRN ║
╚═════════════════════════════════════════════════════════════════════════╝
───────────────────────────────────────────────────────────────────────────────
KEY FUNCTION COMMENT
───────────────────────────────────────────────────────────────────────────────
F Find Record. With this function you can find a record in any
file by any key.
E Edit Record. Edit the highlighted record.
D Delete Record. The highlighted record and subrecords are deleted.
A Add Record. Allows addition of a new record to the file.
C Copy Record. Same as Add but copies fields from current record.
Q Quit to Menu. Quit back to the main menu.
N Next Record. The next record will be displayed.
P Previous Record. The Previous record will be displayed.
T First Record. The first record will be displayed.
L Last Record. The last record will be displayed.
+/- Switch Files. Switch to next or previous file in Database.
───────────────────────────────────────────────────────────────────────────────
───────────────────────────────────────────────────────────────────────────────
─* EDIT MODE KEYS *─
───────────────────────────────────────────────────────────────────────────────
F1 Abort Edit/Add. This key may be used to Abort the Edit or Add
functions. The data files will not be updated.
F5 Delete Field. The field is deleted from the cursor position to
the end of the field and the cursor is placed at
the left margin of the field.
F9 Done Edit/Add. This key is used to end editing. The record is
written to the data files.
Tab key Skip to margin. This function will skip to start or end of field
contents.
─┘ key End field edit. This key will end editing in the current field.
The cursor is moved to the next field.
─ Backspace. This key will cause the cursor to move left and
erase the character to the left.
Ins Insert Toggle. This key will toggle the insert mode On/Off.
Del Delete char. The character under the cursor will be deleted.
Field Up. This key is used to move to the previous field.
Field Down. This key is used to move to the next field.
Cursor Left. This key moves the cursor to the left.
Ü Cursor right. This key moves the cursor to the right.
───────────────────────────────────────────────────────────────────────────────
Volume in drive A has no label
Directory of A:\
FILE1981 TXT 4589 1-04-90 11:53a
FILES_5 DOC 507 2-12-89 11:23a
GO BAT 38 1-01-80 1:37a
GO TXT 771 1-01-80 3:40a
HELP TXT 2762 9-22-87 1:25a
MANUAL DOC 6345 2-12-89 1:07p
MESSAGE 1 178 1-01-80 12:51a
NEC COM 19049 1-01-80 1:51a
RUN BAT 64 1-01-80 12:47a
SBMIO COM 11291 9-22-87 1:25a
SBMSIO CHN 27209 9-22-87 1:25a
THREXFMR CHN 23128 1-01-80 12:35a
YOURSYS COM 26516 9-22-87 1:25a
13 file(s) 122447 bytes